1.
The Journal of Korean Academy of Prosthodontics ; : 234-244, 2023.
Article in English | WPRIM | ID: wpr-1002885

ABSTRACT

Tooth wear refers to the loss of dental hard tissue caused by various physiological and pathological causes, and excessive pathological wear can cause complications such as pathological changes in dimensions, occlusal disharmony, loss of function, and aesthetic problems. The cause of tooth wear can be caused by attrition, abrasion, corrosion and abfraction, and it is known to act in a multifactorial etiology in interocclusal activity. In patients with excessive pathological wear, it is important to determine whether or not the vertical dimension of occlusion is reduced, and complete oral rehabilitation should be achieved with the adaptation of the neuromuscular and temporomandibular joint through accurate diagnosis and analysis. The patient in this case was a 63-year-old male patient, who presented discomfort to cold beverage due to severe tooth wear. After analysis of the patient’s vertical dimension of occlusion, a full mouth rehabilitation was performed with increasing vertical dimension of occlusion. The goal of treatment was to improve the occlusal plane with the equal-intensity contact of all teeth, harmonious anterior guidance and immediate disclusion of all posterior contacts. After rehabilitation, the patient was satisfied with function and esthetic appearance.

2.
The Journal of Advanced Prosthodontics ; : 126-135, 2023.
Article in English | WPRIM | ID: wpr-1002876

ABSTRACT

PURPOSE@#. The aim of this study was to evaluate the reliability of implant stability measuring devices depending on the location of the implant and the position of the patient. @*MATERIALS AND METHODS@#. Six implants were installed in different dentate sextants of six artificial bone models. Implant stability was measured in three conditions of the bone model (without mounting on a phantom head, mounted on a phantom head in supine position, and mounted on a phantom head in upright position). A resonance frequency analysis device (Osstell) and two damping capacity analysis devices (Periotest and Anycheck) were used to measure implant stability. The values measured outside the phantom head were treated as controls, and the values inside the phantom head were compared using an independent t-test. @*RESULTS@#. Osstell showed different results in two of the six divisions in both the supine and upright positions compared to outside of the mouth (P < .05). Periotest showed different results in all six parts in the supine position and in five parts in the upright position compared to outside of the mouth (P < .05). While Anycheck showed different results in five areas in the supine position compared to outside of the mouth, it showed different results in only one area in the upright position (P < .05). @*CONCLUSION@#. In the difficult implant position for the operator to access, the implant stability measuring devices show less reliability. The accessibility of implant is greatly affected in the order of Osstell, Anycheck, and Periotest. [J Adv Prosthodont 2023;15:126-35]

3.
The Journal of Korean Academy of Prosthodontics ; : 305-313, 2021.
Article in English | WPRIM | ID: wpr-903500

ABSTRACT

Purpose@#The purpose of this pilot study is to evaluate the reliability and validity of the Korean version of the oral health impact profile (OHIP-EDENT K) for edentulous patients. @*Materials and Methods@#The study was conducted on 12 patients who fabricated overdenture in the Department of Prosthodontics, Korea University, Guro Hospital. All subjects completed the Korean version of Oral Health Impact Profile (OHIP K) questionnaire. Shorten version of the OHIP called OHIP-14 K and OHIP-EDENT K were derived from the datasets. Cronbach's alpha was used to measure internal consistency of the summary scores for OHIP-EDENT K. The Spearman's correlation coefficient between the summary scores for OHIP-EDENT K and OHIP K was calculated to evaluate concurrent validity. @*Results@#The reliability of the summary scores for OHIP-EDENT K was acceptable (α=.736). The Spearman's correlation coefficient of the summary scores for OHIP-EDENT K and OHIP K was 0.966, which was statistically significant (P<.001). OHIP-EDENT K exhibited less susceptibility to floor effects than OHIP-14 K and appeared to measure change as effectively as OHIP K. In order to prove the reliability, responsiveness and validity of OHIP-EDENT K, further studies with more samples are needed. @*Conclusion@#The OHIP-EDENT K, a questionnaire on oral health-related QOL comprising 19 items, has measurement properties comparable with the full 49-item version. This modified shortened version can be an alternative questionnaire to full version of OHIP K and OHIP-14 K in edentulous patients.

4.
The Journal of Advanced Prosthodontics ; : 117-125, 2021.
Article in English | WPRIM | ID: wpr-903462

ABSTRACT

. Implants were placed immediately after tooth extraction on anterior alveolar ridges in the maxilla and mandible. The pinguide system was used to help determine the location and path of implants during the surgical process. The horizontal distance from implants to the outer border of alveolar bone was measured at the rim and middle of the implants in the cone beam computed tomography images. The alteration of alveolar bone was evaluated comparing the horizontal distances measured immediately after surgery and 3 months after surgery. RESULTS. The results show that more resorption occurred towards the labial bone than the lingual bone in the maxilla.A similar amount of labial and lingual bone resorption was observed in the mandible. CONCLUSION. Considering the horizontal alteration of alveolar bone, labio-lingual positioning of the implant towards the lingual bone in the maxilla and at the center of the alveolar ridge in the mandible is recommended when it is placed immediately after tooth extraction.

5.
The Journal of Korean Academy of Prosthodontics ; : 305-313, 2021.
Article in English | WPRIM | ID: wpr-895796

ABSTRACT

Purpose@#The purpose of this pilot study is to evaluate the reliability and validity of the Korean version of the oral health impact profile (OHIP-EDENT K) for edentulous patients. @*Materials and Methods@#The study was conducted on 12 patients who fabricated overdenture in the Department of Prosthodontics, Korea University, Guro Hospital. All subjects completed the Korean version of Oral Health Impact Profile (OHIP K) questionnaire. Shorten version of the OHIP called OHIP-14 K and OHIP-EDENT K were derived from the datasets. Cronbach's alpha was used to measure internal consistency of the summary scores for OHIP-EDENT K. The Spearman's correlation coefficient between the summary scores for OHIP-EDENT K and OHIP K was calculated to evaluate concurrent validity. @*Results@#The reliability of the summary scores for OHIP-EDENT K was acceptable (α=.736). The Spearman's correlation coefficient of the summary scores for OHIP-EDENT K and OHIP K was 0.966, which was statistically significant (P<.001). OHIP-EDENT K exhibited less susceptibility to floor effects than OHIP-14 K and appeared to measure change as effectively as OHIP K. In order to prove the reliability, responsiveness and validity of OHIP-EDENT K, further studies with more samples are needed. @*Conclusion@#The OHIP-EDENT K, a questionnaire on oral health-related QOL comprising 19 items, has measurement properties comparable with the full 49-item version. This modified shortened version can be an alternative questionnaire to full version of OHIP K and OHIP-14 K in edentulous patients.

6.
The Journal of Advanced Prosthodontics ; : 117-125, 2021.
Article in English | WPRIM | ID: wpr-895758

ABSTRACT

. Implants were placed immediately after tooth extraction on anterior alveolar ridges in the maxilla and mandible. The pinguide system was used to help determine the location and path of implants during the surgical process. The horizontal distance from implants to the outer border of alveolar bone was measured at the rim and middle of the implants in the cone beam computed tomography images. The alteration of alveolar bone was evaluated comparing the horizontal distances measured immediately after surgery and 3 months after surgery. RESULTS. The results show that more resorption occurred towards the labial bone than the lingual bone in the maxilla.A similar amount of labial and lingual bone resorption was observed in the mandible. CONCLUSION. Considering the horizontal alteration of alveolar bone, labio-lingual positioning of the implant towards the lingual bone in the maxilla and at the center of the alveolar ridge in the mandible is recommended when it is placed immediately after tooth extraction.

7.
The Journal of Advanced Prosthodontics ; : 83-88, 2020.
Article | WPRIM | ID: wpr-837203

ABSTRACT

PURPOSE@#. The purpose of this in vitro study was to examine the reliability of the Anycheck device and the effect of the healing abutment diameter on the Anycheck values (implant stability test, IST). @*MATERIALS AND METHODS@#. Thirty implants were placed into three artificial bone blocks with 10 Ncm, 15 Ncm, and 35 Ncm insertion torque value (ITV), respectively (n = 10). (1) The implant stability was measured with three different kinds of devices (Periotest M, Osstell ISQ Mentor, and Anycheck). (2) Five different diameters (4.0, 4.5, 4.8, 5.5, and 6.0 mm) of healing abutments of the same height were connected to the implants and the implant stability was measured four times in different directions with Anycheck. The measured mean values were statistically analyzed. @*RESULTS@#. The correlation coefficient between the mean implant stability quotient (ISQ) and IST value was 0.981 (P<.01) and the correlation coefficient between the meant periotest value (PTV) and IST value was -0.931 (P<.01). There were no statistically significant differences among the IST values with different healing abutment diameters. @*CONCLUSION@#. There was a strong correlation between the Periotest M and Anycheck values and between the ISQ and IST. The diameter of the healing abutment had no effect on the Anycheck values.

8.
The Journal of Advanced Prosthodontics ; : 47-50, 2015.
Article in English | WPRIM | ID: wpr-220554

ABSTRACT

PURPOSE: This study aimed to discover a way to increase the bond strength between bis-acryl resins, using a comparison of the shear bond strengths attained from bis-acryl resins treated with light curing, pressure, oxygen inhibition, and heat. MATERIALS AND METHODS: Self-cured bis-acryl resin was used as both a base material and as a repair material. Seventy specimens were distributed into seven groups according to treatment methods: pressure - stored in a pressure cooker at 0.2 Mpa; oxygen inhibition- applied an oxygen inhibitor around the repaired material,; heat treatment - performed heat treatment in a dry oven at 60degrees C, 100degrees C, or 140degrees C. The shear bond strength was measured with a universal testing machine, and the shear bond strength (MPa) was calculated from the peak load of failure. A comparison of the bond strength between the repaired specimens was conducted using one-way ANOVA and Tukey multiple comparison tests (alpha=.05). RESULTS: There were no statistically significant differences in the shear bond strength between the control group and the light curing, pressure, and oxygen inhibition groups. However, the heat treatment groups showed statistically higher bond strengths than the groups treated without heat, and the groups treated at a higher temperature resulted in higher bond strengths. Statistically significant differences were seen between groups after different degrees of heat treatment, except in groups heated at 100degrees C and 140degrees C. CONCLUSION: Strong bonding can be achieved between a bis-acryl base and bis-acryl repair material after heat treatment.


Subject(s)
Hot Temperature , Oxygen
9.
The Journal of Advanced Prosthodontics ; : 145-151, 2011.
Article in English | WPRIM | ID: wpr-172522

ABSTRACT

PURPOSE: This study was performed to investigate the ability of recombinant human-bone morphogenic protein-2 immobilized on a heparin-grafted bone substrate to enhance the osteoblastic functions. MATERIALS AND METHODS: The Bio-Oss(R), not coated with any material, was used as a control group. In rhBMP-2-Bio-Oss(R) group, rhBMP-2 was coated with Bio-Oss(R) using only deep and dry methods (50 ng/mL, 24 h). In heparinized rhBMP-2-Bio-Oss(R) group, dopamine was anchored to the surface of Bio-Oss(R), and coated with heparin. rhBMP-2 was immobilized onto the heparinized- Bio-Oss(R) surface. The release kinetics of the rhBMP-2-Bio-Oss(R) and heparinized rhBMP-2-Bio-Oss(R) were analyzed using an enzyme-linked immunosorbent assay. The biological activities of the MG63 cells on the three groups were investigated via cytotoxicity assay, cell proliferation assay, alkaline phosphatase (ALP) measurement, and calcium deposition determination. Statistical comparisons were carried out by one-way ANOVA test. Differences were considered statistically significant at *P<.05 and **P<.001. RESULTS: The heparinized rhBMP-2-Bio-Oss(R) showed more sustained release compared to the rhBMP-2-Bio-Oss(R) over an extended time. In the measurement of the ALP activity, the heparinized group showed a significantly higher ALP activity when compared with the non-heparinized groups (P<.05). The MG63 cells cultivated in the group with rhBMP-2 showed increased calcium deposition, and the MG63 cells from the heparinized group increased more than those that were cultivated in the non-heparinized groups. CONCLUSION: Heparin increased the rhBMP-2 release amount and made sustained release possible, and heparinized Bio-Oss(R) with rhBMP-2 successfully improved the osteoblastic functions.


Subject(s)
Alkaline Phosphatase , Bone Substitutes , Calcium , Cell Proliferation , Dopamine , Enzyme-Linked Immunosorbent Assay , Heparin , Immobilization , Kinetics , Osteoblasts
10.
The Journal of Advanced Prosthodontics ; : 152-160, 2011.
Article in English | WPRIM | ID: wpr-172521

ABSTRACT

PURPOSE: This study was to investigate the effects of recombinant human platelet-derived growth factor (rhPDGF-BB) and heparin to titanium surfaces for enhancement of osteoblastic functions and inhibition of inflammation activity. MATERIALS AND METHODS: The anodized titanium discs, not coated with any material, were used as a control group. In heparinized- Ti group, dopamine was anchored to the surface of Ti substrates, and coated with heparin. In PDGF-Ti group, rhPDGF-BB was immobilized onto heparinized Ti surface. The surface morphologies were investigated by the scanning electron microscope in each group. The release kinetics of rhPDGF-BB were analyzed, and cytotoxicity tests for each group were conducted. The biocompatibilities were characterized by measuring cell proliferation, alkaline phosphatase activity, and calcium deposition using MG-63 cells. Statistical comparisons were carried out by one-way ANOVA tests. Differences were considered statistically significant at *P<.05 and **P<.001. RESULTS: The combination of rhPDGF-BB and heparin stimulated alkaline phosphatase activity and OCN mRNA expression in osteoblastic cells (*P<.05 and **P<.001). MG-63 cells grown on PDGF-Ti had significantly higher amounts of calcium deposition than those grown on anodized Ti (**P<.001). Heparinized Ti was more anti-inflammatory compared to anodized Ti, when exposed to lipopolysaccharide using the transcript levels of TNF-alpha and IL-6 of proinflammatory cytokine (*P<.05 and **P<.001). CONCLUSION: The result of this study demonstrated that the incorporation of rhPDGF-BB and heparin onto Ti surface enhanced osteoblastic functions and inhibited inflammation.


Subject(s)
Humans , Alkaline Phosphatase , Calcium , Cell Proliferation , Dopamine , Electrons , Heparin , Immobilization , Inflammation , Interleukin-6 , Kinetics , Osteoblasts , Platelet-Derived Growth Factor , Proto-Oncogene Proteins c-sis , RNA, Messenger , Titanium , Tumor Necrosis Factor-alpha